Tag |
Refractory long distance communication tag |
DS-1TG |
I/F between tag and reader/writer |
Wireless communication standard |
Compliant with ISO 18000-4
|
Communication frequency/method |
Central frequency 2.45GHz/microwave
|
Recommended transmission distance *1 |
For DS-10RW
|
Reading: from 30 to 800mm
Writing: from 30 to 800mm
|
For DS-5RW
|
Reading: from 30 to 280mm
Writing: from 30 to 280mm
|
Transmission time |
Reading data (8 byte): 12msec or less, Writing data (1 byte): 25msec or less
|
Rewritability |
Over 100,000 times
|
Memory capacity |
224 byte (User area: 206 byte)
|
Operation ambient temperature |
In saving data |
From -55 to 150 degree Celsius *2
|
In reading/writing data |
From -40 to 85 degree Celsius
|
Operation ambient humidity |
No condensing
|
Storage ambient temperature |
From -55 to 95 degree Celsius
|
Vibration resistance |
Compliant with JIS 60068-2-6: 1999 (from 10 to 55Hz, double amplitude 2mm, 2 hours each in X, Y, and Z directions)
|
Shock resistance |
Compliant with JIS 60068-2-27: 1995 (980m/s2, 6ms, 3 times each in X, Y, and Z directions)
|
Protective structure |
IEC standard IP-67 (dust-proof, water-proof)
|
Chemical resistance |
Neutral/Alkaline detergent can be used
|
Case material |
PEI: polyetherimide
|
Dimensions (mm) |
86.5 x 15.6 x 7.9
|
Weight |
Approx. 8g
|
|
*1 |
The maximum range in a condition where there are no obstacles nor things using the same wave length. The range may vary in a different condition. |
*2 |
As long as the total time of exposure to high temperature from 95 to 150 degree Celsius does not exceed 1,000 hours, this product can tolerate temperature cycle from 0 to 150 degree Celsius up to 2,000 times. |
Tag |
Long range tag |
Tag for metallic objects |
RZ-1TG4 |
RZ-2TG1A |
Memory capacity *3 |
User area |
110 bytes |
System area |
18 bytes |
Possible rewriting times |
More than 100,000 times |
Operation ambient temperature
(degree Celsius) |
-30 to 85 |
-40 to 85 |
Protective structure |
JIS C 0920 Protection Standard Class 7(water resistant) |
Weight (g) |
About 24 |
About 8 |
|
Reader/writer with an integrated antenna |
Short distance type |
Intermediate distance type |
DS-5RW |
DS-10RW
|
Radio station type |
Premises radio station (applied standard: RCR STD-1)
*license needed |
Communication system |
Supporting Intellitag protocol (Compliant with ISO 18000-4) |
Transmission frequency |
2450MHz(2427MHz to 2470.75MHz)/ narrow-band system, variable with 5MHz steps |
Output power |
300mW |
Transmission speed |
Between reader/writer and tag: 40kbps |
Transmission distance
(Maximum *4)
(mm) |
Long range tag
(RZ-1TG4) |
Reading: 50 to 650 (1,000),
Writing: 50 to 650 (650) |
Reading: 50 to 1,300 (2,000),
Writing 50 to 1,300 (1,300) |
Tag for metallic objects
(RZ-2TG1A) |
Reading: 30 to 250 (400),
Writing: 30 to 250 (250) |
Reading: 30 to 650 (1,000),
Writing 30 to 650 (650) |
CM tag
(RI-3TG3) |
Reading: 0 to 100 (170),
Writing: 0 to 100 (100) |
Reading: 0 to 250 (400),
Writing 0 to 250 (250) |
Power source |
Voltage: 14 to 16V, Current: 400mA(Supplied from ID controller) |
Operation ambient temperature
(degree Celsius) |
-20 to 60 |
Protective structure |
Compliant with IP-65 |
Weight (g) |
About 920 |
About 1,750 |
|
*4 |
The maximum range in a condition where there are no obstacles nor things using the same wave length. The range may vary in a different condition. |
ID controller |
Independent type |
PLC-mount type |
DS-32D |
JW-23DU(for JW300/30H/20H) |
Higher-unit interface |
RS232C/RS422A/DeviceNet
*In case of RS422A or DeviceNet, up to 16 units can be connected. |
PLC bus connection (mounted to the base slot)
*unit type: special I/O |
Reader-writer interface |
Available reader/writer: up to two units, Communication standard: RS422A,
Communication distance: 1km maximum, Power source: supplying 15VDC with the reader/writer
|
Parallel I/O interface |
Input: two points(24VDC, 5.5mA)
Output: two points(5VDC to 24VDC, 50mA per point, NPN transistor output)
|
--- |
Peripheral device interface |
RS232C/RS422A, supporting the same special command as is used in higher-level interface |
Power source |
For controller and antenna: 24VDC +/-10%,
600mA (Using special external power source) |
For controller: 5VDC, 300mA(Supplying from PLC)
For reader/writer: 24VDC, 400mA(Using special external power source) |
Operation ambient temperature
(degree Celsius) |
0 to 55 |
Protective structure |
No waterproof |
Weight (g) |
About 400 |
About 300 |
|
Dimensions(unit:mm)
|